Wacker E1100

Available For Rent
Available For Purchase


The hydronic surface heater product line is designed to quickly, easily and economically thaw frozen ground, cure concrete, prevent frost and provide temporary air heat during cold weather conditions. The E1100 thaws up to 2,200 sq. ft. of frozen ground at an average of one-foot-deep per day. The E 1100 will also set, finish and cure 2,200 sq. ft. of concrete; up to 6,600 sq. ft. with accessories. At 85% efficiency, the E 100 offers the highest in the industry.

- With 1,100 ft. of hose and a hydraulic hose system, the E 1100 allows for single     person set-up and placement, for greater flexibility on all applications.

- Positive displacement pump provides maximum flow and consistent heat delivery for thawing and curing. One pump per hose loop means delivery of maximum Btu's per hour.

- Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications.
        
- Performance monitoring strobe light indicates from a distance that all systems are operating properly. Low power requirements: operates from a single 115V, 20 Amp outlet.
        
- Options include a 3.5 kW air cooled diesel generator with sound attenuated enclosure and on-board load management system to prevent wet stacking.

Product files and documents

 
E1100 PDF file, 372.16 KB


 Specifications

Dimensions (L x W x H)

114 x 65 x 61 in

Operating weight

2,787 lb

Shipping weight Dry

2,283 lb

Heat transfer fluid Capacity

50 US gal

Hose Length

1,100 ft

Quantity Hose Reels

1

Quantity Circulation Loops

1

Hose pressure Normal Operating

90 psi

Heating power Gross Input

122,080 BTU/h

Heat efficiency

87%

Operating temperature

180º F

Capacity Thaw (Std)

2,200 ft2

Capacity Thaw (w/Acc)

3,300 ft2

Capacity Cure (Std)

2,200 ft2

Capacity Cure (w/Acc)

6,600 ft2

Capacity Frost (Std)

3,300 ft2

Capacity Frost (w/Acc)

9,900 ft2

Capacity Air Heat W/Acc

180,000 ft3

Rated current

20 A

Rated voltage

120 V